AMTAX sc: High precision process-instrument for the determination of ammonium in water, waste water and activated sludge. Outdoor enclosure. Incl. filter probe with 5m hose. 230V AC/50 Hz power supply.
- Automatic cleaning and calibration
- Wall mountable, rail mountable and mountable on a stand
- With integrated filter probe
- Many additional versions available on request
The sample preparation is done by an integrated sample preparation probe with 5 m heated hose. The filtration probe is operating at 230V. Evaluation and operation with SC 1000 Controller. The analyser is equipped with an insulated enclosure for outdoor installation. The sample can be analysed before any degradation. The ammonium in the sample is first converted to gaseous ammonia. Only the NH3 gas passes through the gas-permeable membrane of the electrode and is detected. This method guarantees a wide measuring range and is less susceptible to cross-sensitivity methods that make use of an ion-selective electrode (ISE). in situ membrane filtration; filter modules are exchangeable.
Back to the top.
SC 1000: Local measurement of several parameters
Probe module for connecting up to 4 SC sensors, with analogue output card with 4 x 0/4-20mA OUTPUT, relay card with 4 break contacts (NC), and EU power cord for 100-240V AC power supply.
- Flexible: individually configurable
- Future-safe: always expandable
- Intuitive operation: display with touchscreen
- Many additional versions available on request
A controller system to which SC sensors can be connected and from which they can be controlled consists of a single SC 1000 display module and one or more SC 1000 probe modules. The system is configured modularly in line with customer-specific requirements and can be expanded at any time with additional measurement stations, sensors, inputs, outputs and bus interfaces.
The probe module is used to connect SC sensors to a measurement station. Several probe modules can be linked to create a SC 1000 network.
Back to the top.
RTC-N/DN
RTC105 N/DN Module, 1-channel, intermittent, VFD control
Control module for load-dependant regulation of nitrification and denitrification times. 1-channel version for intermittently operating WWTPs. With DO step control (6x digital + 2x FU).
- Load-dependent aeration
- Stable nitrogen discharge values
- Reduced energy consumption
- Simple installation
The real-time controller optimises nitrogen elimination at biological waste water treatment plants that are operated either intermittently or in SBR mode (SBR reactors).
Based on the current ammonium and nitrate load, the module automatically calculates when aeration should occur and to what intensity, so that the required discharge values can be reliably met.
The run time of the blowers can also be reduced by setting the load-dependent nitrification and denitrification times, thereby lowering energy costs.
Back to the top.
AN-ISE: Combination sensor for ammonium and nitrate
AN-ISE sc with RFID Low cost ISE combination Ammonium and Nitrate probe (immersion), 10m cable
Carries out continuously direct measurements using an ion-selective electrode. No need for reagents or sample preparation. Compensated interference by potassium and chloride.
- Reliable results for ammonium and nitrate
- Easy handling with CARTRICAL plus
- Simple and intuitive operation
- Always under control
- Rely on Hach's application know how
The special feature of the probe is the CARTRICAL technology. This provides reliable measured values and considerably reduced maintenance time and costs in comparison with conventional ISE probes.
The complete system - SC controller has to be ordered separately - comes from a single supplier. The probe is installed on the side of the tank. The measuring system can be extended to include an automatic cleaning unit with a compressor.
Back to the top.
NITRATAX: Reagent-free method. Multiple beam absorption photometer with a flash lamp, turbidity compensation through reference measurement. Lowered directly into the sample stream (flow-through unit optional).
- UV absorption method-proven, continuous, and precise
- Eliminates reagents, sampling, and sample conditioning
- Self-cleaning probe
- Measurement in activated sludge or in water
- Life-long factory calibration
Stainless steel probe. UV beams are projected across a gap for immediate measurement of the nitrate content in water, wastewater and activated sludge. The measuring windows are cleaned by a wiper. Evaluation by SC controller. The simple mounting and easy handling of the probe is guaranteed by a specially designed tank rim mounting hardware. In order to place the controller near the probe, the tank rim mounting hardware for sc controller should be used. The through-flow variant is used wherever submersible installation is not possible for construction related reasons or the medium makes it necessary to measure a filtered sample (very high TS contents, sewage treatment plant inlet, etc.).
Back to the top.
LDO sc: The new LDO generation - even simpler, even more reliable and even more cost-effective
Immersion or flow-through probe with optical luminescence measuring method. Calibration-free & drift-free.
- Extremely reliable - 36-month warranty on probe
- The optimised temperature sensor and the new 3D factory calibration make O2 measurement even more accurate
- No electrolyte or membrane changes necessary
- Remote functions for simple and convenient data transfer via Internet and SMS
No electrolyte or membrane changes due to the optical measurement method. The new LDO probe ensures there is only a minimal amount of maintenance. The luminescence method means the measurement is unaffected by any type of interference.
Years of practical experience have shown that this method completely overcomes the disadvantages of traditional electrochemical O2 measurement methods.
Back to the top.