The EZ Series Online Analysers offer multiple options to monitor Alkalinity in water. Typical applications are wastewater, drinking water, steam & power generation, surface water.
The EZ4000 Series Alkalinity Analysers are single-parameter titrators: - EZ4003 Free Alkalinity - EZ4004 Total Alkalinity Standard measuring range: 10 - 5000 mg/L CaCO3
The EZ5000 Series Alkalinity Analysers are multi-parameter titrators: - EZ5001 Total Alkalinity & Free Alkalinity - EZ5003 Total Hardness & Free Alkalinity - EZ5004 Total Hardness & Total Alkalinity - EZ5005 Total Hardness & Total Alkalinity & Free Alkalinity - EZ5006 Total Hardness & Total Calcium Hardness & Total Alkalinity & Free Alkalinity Standard measuring range for Alkalinity: 10 - 5000 mg/L CaCO3 Total Hardness: 10 - 1000 mg/L CaCO3
Options for all analysers include: - Calibration to 10%, 25% or 50% of standard range - Multiple stream analysis (1-8 streams) reducing cost per sampling point - Analogue and/or digital outputs for communication
Alkalinity can also be measured in combination with Volatile Fatty Acids (VFA) to monitor digestion processes. For this option please check the EZ7200 Series Analyser page.
Some applications may require the use of a sampling/filtration or an external dilution system for sample preconditioning. For this option please check the EZ9000 Sample preconditioning page.
Use the filters in the table below to find your Alkalinity analyser. Need support or a different configuration? Please contact us.
Volatile fatty acids (VFAs), bicarbonate, total alkalinity, partial alkalinity
VFAs 10 - 500 mg/L as acetate equivalent; Bicarbonate 1 - 50 meq/L or 5000 mg/L as CaCO3; Alkalinity, total and Alkalinity, partial 1 - 50 meq/L or 5000 mg/L as CaCO3
Modbus RS485
Optional: Active 4 - 20 mA max. 500 Ohm load, 1 to 8 outputs RS232, Modbus TCP/IP
Volatile fatty acids (VFAs), bicarbonate, total alkalinity, partial alkalinity
VFAs 20 - 1000 mg/L as acetate equivalent; Bicarbonate 1 - 50 meq/L or 5000 mg/L as CaCO3; Alkalinity, total and Alkalinity, partial 0 - 50 meq/L or 5,000 mg/L as CaCO3
Modbus RS485
Optional: Active 4 - 20 mA max. 500 Ohm load, 1 to 8 outputs RS232, Modbus TCP/IP
Volatile fatty acids (VFAs), bicarbonate, total alkalinity, partial alkalinity
VFAs 100 - 5000 mg/L as acetate equivalent; Bicarbonate 5 - 100 meq/L or 10,000 mg/L as CaCO3; Alkalinity, total and Alkalinity, partial 0 - 100 meq/L or 10,000 mg/L as CaCO3
Modbus RS485
Optional: Active 4 - 20 mA max. 500 Ohm load, 1 to 8 outputs RS232, Modbus TCP/IP